Locinox INTRALEC Electric Keep Setup & Installation Guide
Learn how to install and wire the Locinox INTRALEC Built-in Electric Keep for Fortylock, Fiftylock, and Sixtylock insert locks. Available to order today from First Fence, this flush-mounted electric strike integrates directly into metal gate posts to provide seamless electronic access control for swing gates.
✨ Key Features
⚡ Electronic Access Control: Connects with keypads, card readers, and intercom systems for automated remote gate unlocking.
🔄 Fail-Safe & Fail-Secure: Configurable wiring terminals for both Fail Open (Ruptura) and Fail Close (Emissa) modes across 12V–24V AC/DC.
🔒 Mortise Lock Integration: Engineered specifically for use with Locinox Fortylock, Fiftylock, and Sixtylock insert locks.
🛡️ Flush Post Mounting: Conceals within 40mm, 50mm, or 60mm post profiles for a sleek, tamper-resistant installation.
⚡ Fast Click-It Installation: Features an internal clamping system for fast positioning and securing inside the post profile cutout.
🛠️ Quick Installation Steps
Post Preparation: Cut out the designated slot dimensions (240mm height, 32mm width) into the gate post profile.
Wire Terminal Block: Wire the electrical connection for Fail Open (NC) or Fail Close (NO) operation as required by your security setup.
Mount Keep Unit: Slide the INTRALEC keep into the cutout slot and tighten the Click-It expansion mechanism with a hex key.
Test Electronic Release: Connect power, align with the gate lock latch, and test keypad/intercom release functionality.