SKU: WEB-01317

BOX/K-150 - Solid Wall Standard Load Bearing Box Lintel - 215mm High

Pay in 3 Payments at 2.5% interest with
Available to UK Limited businesses only
Images shown are for illustration purposes only and may differ slightly
2850mm Length
LINT-BOXK150-2850
3 Weeks Lead Time
£360.33
each
Quantity
3000mm Length
LINT-BOXK150-3000
3 Weeks Lead Time
£379.56
each
Quantity
3150mm Length
LINT-BOXK150-3150
3 Weeks Lead Time
£426.29
each
Quantity
3300mm Length
LINT-BOXK150-3300
3 Weeks Lead Time
£426.29
each
Quantity
3450mm Length
LINT-BOXK150-3450
3 Weeks Lead Time
£464.37
each
Quantity
3600mm Length
LINT-BOXK150-3600
3 Weeks Lead Time
£464.37
each
Quantity
3750mm Length
LINT-BOXK150-3750
3 Weeks Lead Time
£564.17
each
Quantity
3900mm Length
LINT-BOXK150-3900
3 Weeks Lead Time
£574.98
each
Quantity
4050mm Length
LINT-BOXK150-4050
3 Weeks Lead Time
£618.65
each
Quantity
4200mm Length
LINT-BOXK150-4200
3 Weeks Lead Time
£618.65
each
Quantity
4350mm Length
LINT-BOXK150-4350
3 Weeks Lead Time
£743.65
each
Quantity
4500mm Length
LINT-BOXK150-4500
3 Weeks Lead Time
£743.65
each
Quantity
4650mm Length
LINT-BOXK150-4650
3 Weeks Lead Time
£793.19
each
Quantity
4800mm Length
LINT-BOXK150-4800
3 Weeks Lead Time
£793.19
each
Quantity
£0.00 EACH
Exact delivery cost added during basket checkout
£0.00 incl VAT

Product Description

BOX/K-150 - Solid Wall Standard Load Bearing Box Lintel - 215mm high

This standard load-bearing box lintel has been created to support standard loads for either internal or external openings. These lintels are suitable for use on walls that are 150mm in width. Along the sides of the lintel, there are multiple small holes, which act as a plaster key.

This range of solid wall box lintels has been constructed from high-quality pre-galvanised steel, which is 2.5mm thick. The box lintels have been designed so that they are able to bear the full weight of wet masonry as soon as they have been installed.

The BOX/K-150 solid wall lintels are available in 150mm increments, starting at 2850mm up to 4800mm. This allows for load-bearing over a wide variety of gap sizes for applications such as windows or doors. 
Please note: The lintels require an additional 150mm end bearing for each end of the lintel. For example, if the gap required to bridge is 3900mm long, then an additional 300mm will need to be added to the lintel’s total length.

In order for this lintel to support the specified loads below, the lintel will need to be installed correctly. Care should also be taken to avoid shock loading on box lintels when used with concrete floors or any other heavy units.

The figures also take into account the different loading types, which are common in traditional cavity wall construction. These figures have been acquired through testing in accordance with the requirements of standards BS 5977 Part 2: 1983 and BS EN 845-2:2003

If the bearing of a heavier load is required, we can also provide a heavy-duty load-bearing box lintel (HDBOX/K-150).

Length (150mm increments)Steel Thickness (mm)Total UDL kN
2850 - 36002.535
3750 - 42002.530
4350 - 48002.525

Contact Us

If you have any questions or need advice, please get in touch with us. We are available by phone on 01283 512 111, email sales@firstfence.co.uk, or via live chat.

Specifications & Downloads

MaterialPre-Galvanised Steel
Width150mm
Height215mm
Length2850mm-4800mm
Steel Thickness2.5mm

Specifications & Downloads

MaterialPre-Galvanised Steel
Width150mm
Height215mm
Length2850mm-4800mm
Steel Thickness2.5mm

Product Description

BOX/K-150 - Solid Wall Standard Load Bearing Box Lintel - 215mm high

This standard load-bearing box lintel has been created to support standard loads for either internal or external openings. These lintels are suitable for use on walls that are 150mm in width. Along the sides of the lintel, there are multiple small holes, which act as a plaster key.

This range of solid wall box lintels has been constructed from high-quality pre-galvanised steel, which is 2.5mm thick. The box lintels have been designed so that they are able to bear the full weight of wet masonry as soon as they have been installed.

The BOX/K-150 solid wall lintels are available in 150mm increments, starting at 2850mm up to 4800mm. This allows for load-bearing over a wide variety of gap sizes for applications such as windows or doors. 
Please note: The lintels require an additional 150mm end bearing for each end of the lintel. For example, if the gap required to bridge is 3900mm long, then an additional 300mm will need to be added to the lintel’s total length.

In order for this lintel to support the specified loads below, the lintel will need to be installed correctly. Care should also be taken to avoid shock loading on box lintels when used with concrete floors or any other heavy units.

The figures also take into account the different loading types, which are common in traditional cavity wall construction. These figures have been acquired through testing in accordance with the requirements of standards BS 5977 Part 2: 1983 and BS EN 845-2:2003

If the bearing of a heavier load is required, we can also provide a heavy-duty load-bearing box lintel (HDBOX/K-150).

Length (150mm increments)Steel Thickness (mm)Total UDL kN
2850 - 36002.535
3750 - 42002.530
4350 - 48002.525

Contact Us

If you have any questions or need advice, please get in touch with us. We are available by phone on 01283 512 111, email sales@firstfence.co.uk, or via live chat.

Not sure what to buy?

Discover products to complete your solution
01283 512 111
Contact Us
£0.00 EACH
£0.00 incl VAT
Exact delivery cost added during basket checkout