EL/K-90 Cavity Wall Eaves Lintel

SKU: WEB-01303
Images shown are for illustration purposes only and may differ slightly
ProductQtyPrice (ea)Total
Goods Total
Overall Quantity:
0
Total:
£0.00
£0.00
Inner Leaf Width100mm
Outer Leaf Width45mm

Specification

Inner Leaf Width100mm
Outer Leaf Width45mm

Downloads

EL/K-90 Cavity Wall Eaves Lintel

The EL/K-90 wall eaves lintel has been designed to provide support for openings for windows at eaves level. These lintels have a shorter outer leaf which allows the underside of the soffit board to be tightly positioned against the window frame. The inner leaf is 100mm which allows for the support of standard blockwork and also has a plaster key incorporated into the leaf. This range of eaves lintels also uses a thermal break plate on the underside, allowing for superior structural performance.

These eaves lintels are available in 150mm increments starting at 750mm up to 2700mm, making these suitable for a range of window opening lengths.
Please note: For correct installation, the EL/K-90 lintels require 150mm end bearings at each end. For example: if the opening is 1200mm then the lintel length will require an additional 300mm to accommodate for these end bearings.

These eaves lintels have been constructed from high quality pre-galvanised steel mild steel which, depending on the lintel length, is between 1.8mm and 2.5mm thick. The EL/k-90 lintels also satisfy the thermal performance requirements of England and Wales’ part L of the building regulations, Northern Ireland’s part F and Scotland’s technical handbook, section 6.

In order for this lintel to support the specified loads below, the lintel will need to be installed correctly. Please refer to the installation guide for further information.

The figures also take into account the different loading types which are common in traditional cavity wall construction. These lintels have been tested as a composite unit with surrounding masonry and have been built in accordance with BS EN 1996-2:2006. These figures have been acquired through testing in accordance with the requirements of standards BS 5977 Part 2: 1983 and BS EN 845-2:2003
Differential Total UDL kN 19:1 (up to 95% loading on the inner leaf)

Please note: Brickwork cannot be built onto the outer leaf of the EL/K-90 eaves lintel. Any masonry is to be built on the inner leaf only.

Length (150mm increments) Height (mm)Steel Thickness (mm) Total UDL kN 19:1
750 - 15001061.818
1650 - 21001442.020
2250 - 24001632.022
2550 - 27001642.525

EL/K-90 Cavity Wall Eaves Lintel

The EL/K-90 wall eaves lintel has been designed to provide support for openings for windows at eaves level. These lintels have a shorter outer leaf which allows the underside of the soffit board to be tightly positioned against the window frame. The inner leaf is 100mm which allows for the support of standard blockwork and also has a plaster key incorporated into the leaf. This range of eaves lintels also uses a thermal break plate on the underside, allowing for superior structural performance.

These eaves lintels are available in 150mm increments starting at 750mm up to 2700mm, making these suitable for a range of window opening lengths.
Please note: For correct installation, the EL/K-90 lintels require 150mm end bearings at each end. For example: if the opening is 1200mm then the lintel length will require an additional 300mm to accommodate for these end bearings.

These eaves lintels have been constructed from high quality pre-galvanised steel mild steel which, depending on the lintel length, is between 1.8mm and 2.5mm thick. The EL/k-90 lintels also satisfy the thermal performance requirements of England and Wales’ part L of the building regulations, Northern Ireland’s part F and Scotland’s technical handbook, section 6.

In order for this lintel to support the specified loads below, the lintel will need to be installed correctly. Please refer to the installation guide for further information.

The figures also take into account the different loading types which are common in traditional cavity wall construction. These lintels have been tested as a composite unit with surrounding masonry and have been built in accordance with BS EN 1996-2:2006. These figures have been acquired through testing in accordance with the requirements of standards BS 5977 Part 2: 1983 and BS EN 845-2:2003
Differential Total UDL kN 19:1 (up to 95% loading on the inner leaf)

Please note: Brickwork cannot be built onto the outer leaf of the EL/K-90 eaves lintel. Any masonry is to be built on the inner leaf only.

Length (150mm increments) Height (mm)Steel Thickness (mm) Total UDL kN 19:1
750 - 15001061.818
1650 - 21001442.020
2250 - 24001632.022
2550 - 27001642.525